Voltronic +Power Modular UPS

The +Power Modular UPS by Voltronic Power offers unparalleled reliability with its nominal voltage of 3 x 380VAC/400VAC/415VAC. Designed for both balanced and imbalanced loads, it ensures steady voltage regulation, making it a top choice for critical power applications.

Models Covered: +Power 30U-90HV, +Power 30U-120HV, +Power 30U-180HV, +Power 42U-120HV, +Power 42U-210HV, +Power 42U-300HV, +Power 30U-60LV, +Power 42U-80LV, +Power 30U-120LV, +Power 30U-180LV, +Power 42U-140LV

Manufacturer: Voltronic Power Technology Corp.

Application: Ideal for data centers, telecommunications, and industrial applications where uninterrupted power is crucial.

Three Phase Online UPS Unity output power factor Modular design lowers MTTR
Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter +Power 30U-90HV+Power 30U-120HV+Power 30U-180HV+Power 42U-120HV+Power 42U-210HV+Power 42U-300HV
Input
Nominal Voltage 3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)
Voltage Range 305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load305 - 478 VAC @ 100% load; 208 - 478VAC @ 70% load
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz – 70Hz
Power Factor > 0.99 @ 100% Load, >0.98 @ 50% Load
Harmonic Distortion (THDi) < 3% @ 100% load
Output
Nominal Voltage 3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)3 x 380VAC/400VAC/415VAC (3PH+N)
Voltage Regulation (Steady state) ≤ ± 1% Typical (balanced load); ≤ ± 2% Typical (imbalanced load)
Nominal Frequency 50/60Hz
Frequency Range (Synchronized) 46Hz – 54Hz or 56Hz – 64Hz
Overload Capability 1 hour for 110%, 10 mins for 125%, 1 min for 150%, 200ms for >150%
Harmonic Distortion ≤ 2% THD (Linear Load); ≤ 4% THD (Non-linear Load)
Efficiency Up to 94.5%
Battery Charging
Nominal Voltage +/- 216V (12V x 36 pcs)
Maximum Voltage +/- 240V (12V x 40 pcs)
Minimum Voltage +/- 192V (12V x 32 pcs)
Float Charging Voltage 2.25V / Cell
Boost Charging Voltage 2.35V / Cell
Temperature Compensation Yes
Maximum Charging Current (Per Power Module) 8A for 30KW power module6A for 20KW power module
Physical
Cabinet Dimension (D x W x H) mm 1100 x 600 x 14751100 x 600 x 20101100 x 600 x 14751100 x 600 x 14751100 x 600 x 14751100 x 600 x 2010
Net Weight (kg) 675932335 or 333437.5 or 434.5611549
Operating Conditions
Operating Temperature 0 – 40°C
Relative Humidity 0 – 95% non-condensing
Altitude <1000m for Nominal power
IP Protection IP 20
Communication
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Certifications
Safety IEC/EN 60950-1; IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

High efficiency online double conversion technology

Unity output power factor

Modular design lowers MTTR

N+1 or N+X parallel redundancy for power guarantee

Ease of installation and maintenance

Flexible battery configuration adapts different applications

Highly reliable operation with redundant power supply in STS

User-adjustable charging current

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (United Arab Emirates)

Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the +Power Modular UPS?

The +Power Modular UPS offers a high efficiency of up to 94.5% and supports a nominal voltage of 3 x 380VAC/400VAC/415VAC (3PH+N). It maintains a power factor greater than 0.99 at full load and harmonic distortion of less than 3% at 100% load.

Is the +Power Modular UPS compatible with different battery types and solar panels?

Yes, the UPS is compatible with a nominal battery voltage of +/- 216V, consisting of 12V x 36 pcs, and can support a maximum voltage of +/- 240V with 12V x 40 pcs. It can be integrated with solar panels and the grid for enhanced power solutions.

What are the physical specifications of the +Power Modular UPS?

The physical dimensions and weight of the +Power Modular UPS can vary based on the specific configuration and modules used. Please refer to the detailed product manual for precise measurements and weight.

What are the installation requirements for the +Power Modular UPS?

Installation requires a stable environment with appropriate ventilation. The UPS should be installed by a certified technician to ensure compliance with safety standards and optimal performance.

What warranty is offered with the +Power Modular UPS?

Voltronic Power offers a standard warranty period for the +Power Modular UPS, which typically covers parts and labor. Specific warranty terms can vary, so it's advisable to consult the purchase agreement or contact customer support for detailed information.

What certifications and standards does the +Power Modular UPS adhere to?

The +Power Modular UPS is certified under IEC/EN 60950-1, IEC/EN 62040-1, and IEC/EN 62040-2 Category C3, ensuring compliance with international safety and performance standards.

What are the operating conditions for the +Power Modular UPS?

The UPS is designed to operate efficiently in a temperature range that supports optimal performance. It is important to maintain humidity levels within recommended limits to ensure reliability and longevity.

What are the key features and benefits of the +Power Modular UPS?

Key features include high efficiency, robust overload capability, and low harmonic distortion. These benefits ensure reliable power supply, reduced energy costs, and enhanced protection for connected equipment.