Voltronic Galleon III 33/31/11

The Voltronic Power Galleon III 33/31/11 UPS is engineered for superior performance in demanding environments. With a nominal voltage of 3 x 380/400/415VAC or 220/230/240VAC, it ensures stable power delivery with precise voltage regulation in battery mode.

Models Covered: Galleon III 33/31/11 10KL Rack, Galleon III 33/31/11 20KL Rack, Galleon III 33/31/11 20KL-3U Rack

Manufacturer: Voltronic Power Technology Corp.

Application: Ideal for data centers, industrial applications, and critical infrastructure, the Galleon III 33/31/11 provides reliable power backup and protection.

Three Phase Online UPS True double-conversion Rack/Tower design Output power factor 1
Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter Galleon III 33/31/11 10KL RackGalleon III 33/31/11 20KL RackGalleon III 33/31/11 20KL-3U Rack
Input
Nominal Voltage 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
Voltage Range 190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Frequency Range 46-54 Hz or 56-64 Hz
Power Factor >= 0.99 @ 100% load
Output
Output Voltage 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load)
Transfer Time zero
Waveform (Batt. Mode) Pure Sine Wave
Efficiency
AC Mode 95.5%96%96%
ECO Mode 98.5%
Battery Mode 94.5%95.5%95.5%
Battery
Battery Type Depending on application
Numbers ±8 ~ ±10 (adjustable)±16 ~ ±20 (adjustable)±10 ~ ±20 (adjustable)
Charging Current (max.) 1A ~ 18A (adjustable)
Charging Voltage (max.) +/ -13.65V DC x N (N=8~10)+/ -13.65V x N (N=16~20)+/ -13.65V x N (N=10~20)
Physical
Dimension, D X W X H (mm) 620 x 438 x 88 [2U]620 x 438 x 130.6 [3U]620 x 438 x 130.6 [3U]
Net Weight (kgs) 1622.223.1
Operating Conditions
Operation Temperature 0-40°C
Operation Humidity <95% and non-condensing
Noise Level Less than 62dB @ 1 MeterLess than 65dB @ 1 MeterLess than 65dB @ 1 Meter
Communication
Smart RS-232/USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

True double-conversion

Rack/Tower design

Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out

DSP technology guarantees high performance

Output power factor 1

Active power factor correction in all phases

50Hz/60Hz frequency converter mode

ECO mode operation for energy saving (ECO)

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (United Arab Emirates)

Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the Galleon III 33/31/11 UPS?

The Galleon III 33/31/11 UPS offers high efficiency with AC mode at 95.5%, ECO mode at 98.5%, and battery mode at 94.5%. It supports a nominal voltage of 3 x 380/400/415VAC for three-phase or 220/230/240VAC for single-phase systems.

Is the Galleon III 33/31/11 compatible with different battery types or solar panels?

The Galleon III 33/31/11 is designed to be compatible with a variety of battery types. However, it does not directly support solar panel integration without additional equipment.

What are the physical specifications of the Galleon III 33/31/11 UPS?

The physical dimensions and weight of the Galleon III 33/31/11 UPS are not specified in the provided data. Please refer to the product manual for detailed information.

What are the installation requirements for the Galleon III 33/31/11?

Installation of the Galleon III 33/31/11 requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure safety and compliance with local electrical standards.

What warranty is provided with the Galleon III 33/31/11 UPS?

The Galleon III 33/31/11 UPS comes with a standard warranty, which typically covers manufacturing defects. For specific warranty terms, please consult the warranty documentation provided with the product.

What certifications and standards does the Galleon III 33/31/11 adhere to?

The Galleon III 33/31/11 UPS complies with standard certifications, ensuring it meets industry safety and performance standards. Specific certifications are not listed in the provided data.

What are the operating conditions for the Galleon III 33/31/11?

The Galleon III 33/31/11 UPS is designed to operate efficiently within a frequency range of 46-54 Hz or 56-64 Hz. It should be used in environments with controlled temperature and humidity levels.

What are the key features and benefits of the Galleon III 33/31/11 UPS?

Key features of the Galleon III 33/31/11 include zero transfer time, pure sine wave output in battery mode, and a high power factor of >= 0.99 at full load, ensuring reliable and efficient power supply.