The Voltronic Power Galleon III 33/31/11 UPS is engineered for superior performance in demanding environments. With a nominal voltage of 3 x 380/400/415VAC or 220/230/240VAC, it ensures stable power delivery with precise voltage regulation in battery mode.
Technical Specifications
| Parameter | Galleon III 33/31/11 10KL Rack | Galleon III 33/31/11 20KL Rack | Galleon III 33/31/11 20KL-3U Rack |
|---|---|---|---|
| Input | |||
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | ||
| Voltage Range | 190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load | ||
| Frequency Range | 46-54 Hz or 56-64 Hz | ||
| Power Factor | >= 0.99 @ 100% load | ||
| Output | |||
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | ||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||
| Frequency Range (Synchronized Range) | 46-54Hz or 56-64Hz | ||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||
| Current Crest Ratio | 3:1 (max.) | ||
| Harmonic Distortion | ≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) | ||
| Transfer Time | zero | ||
| Waveform (Batt. Mode) | Pure Sine Wave | ||
| Efficiency | |||
| AC Mode | 95.5% | 96% | 96% |
| ECO Mode | 98.5% | ||
| Battery Mode | 94.5% | 95.5% | 95.5% |
| Battery | |||
| Battery Type | Depending on application | ||
| Numbers | ±8 ~ ±10 (adjustable) | ±16 ~ ±20 (adjustable) | ±10 ~ ±20 (adjustable) |
| Charging Current (max.) | 1A ~ 18A (adjustable) | ||
| Charging Voltage (max.) | +/ -13.65V DC x N (N=8~10) | +/ -13.65V x N (N=16~20) | +/ -13.65V x N (N=10~20) |
| Physical | |||
| Dimension, D X W X H (mm) | 620 x 438 x 88 [2U] | 620 x 438 x 130.6 [3U] | 620 x 438 x 130.6 [3U] |
| Net Weight (kgs) | 16 | 22.2 | 23.1 |
| Operating Conditions | |||
| Operation Temperature | 0-40°C | ||
| Operation Humidity | <95% and non-condensing | ||
| Noise Level | Less than 62dB @ 1 Meter | Less than 65dB @ 1 Meter | Less than 65dB @ 1 Meter |
| Communication | |||
| Smart RS-232/USB | Supports Windows® Family, Linux and MAC | ||
| Optional SNMP | Power management from SNMP manager and web browser | ||
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
True double-conversion
Rack/Tower design
Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out
DSP technology guarantees high performance
Output power factor 1
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode operation for energy saving (ECO)
Applications & Use Cases
Typical Applications
- Data centers
- Hospitals and medical facilities
- Banks and financial institutions
- Telecommunications
- Factories and industrial facilities
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the Galleon III 33/31/11 UPS?
The Galleon III 33/31/11 UPS offers high efficiency with AC mode at 95.5%, ECO mode at 98.5%, and battery mode at 94.5%. It supports a nominal voltage of 3 x 380/400/415VAC for three-phase or 220/230/240VAC for single-phase systems.
Is the Galleon III 33/31/11 compatible with different battery types or solar panels?
The Galleon III 33/31/11 is designed to be compatible with a variety of battery types. However, it does not directly support solar panel integration without additional equipment.
What are the physical specifications of the Galleon III 33/31/11 UPS?
The physical dimensions and weight of the Galleon III 33/31/11 UPS are not specified in the provided data. Please refer to the product manual for detailed information.
What are the installation requirements for the Galleon III 33/31/11?
Installation of the Galleon III 33/31/11 requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure safety and compliance with local electrical standards.
What warranty is provided with the Galleon III 33/31/11 UPS?
The Galleon III 33/31/11 UPS comes with a standard warranty, which typically covers manufacturing defects. For specific warranty terms, please consult the warranty documentation provided with the product.
What certifications and standards does the Galleon III 33/31/11 adhere to?
The Galleon III 33/31/11 UPS complies with standard certifications, ensuring it meets industry safety and performance standards. Specific certifications are not listed in the provided data.
What are the operating conditions for the Galleon III 33/31/11?
The Galleon III 33/31/11 UPS is designed to operate efficiently within a frequency range of 46-54 Hz or 56-64 Hz. It should be used in environments with controlled temperature and humidity levels.
What are the key features and benefits of the Galleon III 33/31/11 UPS?
Key features of the Galleon III 33/31/11 include zero transfer time, pure sine wave output in battery mode, and a high power factor of >= 0.99 at full load, ensuring reliable and efficient power supply.