Voltronic Galleon III 33/31/11
The Voltronic Power Galleon III 33/31/11 Online UPS is engineered to deliver superior power protection with its robust voltage capabilities. Designed for both three-phase and single-phase systems, it ensures consistent performance across a wide voltage and frequency range.
Technical Specifications
| Parameter | Galleon III 33/31/11 10K(L) | Galleon III 33/31/11 20K(L) |
|---|---|---|
| Input | ||
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| Voltage Range | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load |
| Frequency Range | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz |
| Power Factor | >= 0.99 @ 100% load | >= 0.99 @ 100% load |
| Harmonic Distortion (THDi) | < 4% @ full linear load | < 4% @ full linear load |
| Output | ||
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% | ± 1% |
| Frequency Range (Synchronized Range) | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) | 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) |
| Transfer Time | Zero | Zero |
| Waveform (Batt. Mode) | Pure Sinewave | Pure Sinewave |
| Bypass | ||
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC(1Ph+N) | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC(1Ph+N) |
| Voltage Range | 305 VAC ~ 457 VAC | 305 VAC ~ 457 VAC |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz |
| Overload Capacity | > 130% : 1 minute (default), continuously working until breaker protection (optional) | > 130% : 1 minute (default), continuously working until breaker protection (optional) |
| Efficiency | ||
| AC Mode | 95.5% | 96% |
| ECO Mode | 98.5% | |
| Battery Mode | 94.5% | 95.5% |
| Battery | ||
| Battery Type | 12V / 9Ah | 12V / 9Ah |
| Numbers (default) | (10+10) pcs | (16+16) pcs |
| Typical Recharge Time | 9 hours recover to 90% capacity | 9 hours recover to 90% capacity |
| Charging Current (max.) | 1A (default) | 1A (default) |
| Charging Voltage | +/-136.5 VDC | +/-218VDC |
| Long-run Model | ±8-10 | ±16-20 |
| Charging Current (max.) | 1A~18A (Adjustable) | 1A~18A (Adjustable) |
| Charging Voltage | +/-13.65V*N (N = 16~20) | +/-13.65V*N (N = 16~20) |
| Physical | ||
| Standard Dimension, D x W x H (mm) | 630 x 250 x 826 | |
| Model Net Weight (kgs) | 80 | 133 |
| Long-run Dimension, D x W x H (mm) | 630 x 250 x 826 | |
| Long-run Model Net Weight (kgs) | 25 | 37 |
| Operating Conditions | ||
| Operation Temperature | 0-40°C | |
| Operation Humidity | <95% and non-condensing | |
| Altitude | 0 ~ 1500m at full load | |
| Noise Level | Less than 62dB @ 1 Meter | Less than 65dB @ 1 Meter |
| Standards | ||
| Safety | EN 62040-1:2008/A1:2013;IEC 62040-1:2008/A1:2013;CE low voltage directive | |
| EMC | EN 62040-2: 2006(C3) CE EMC directive | |
| Communication | ||
| Smart RS-232/USB | Supports Windows® family, Linux and MAC | |
| Optional SNMP | Power management from SNMP manager and web browser | |
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
True double-conversion
Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out
DSP technology guarantees high performance
Output power factor 1.0
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode operation for energy saving (ECO)
Dual AC inputs
Applications & Use Cases
Typical Applications
- Data centers
- Hospitals and medical facilities
- Banks and financial institutions
- Telecommunications
- Factories and industrial facilities
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the Galleon III 33/31/11?
The Galleon III 33/31/11 offers a nominal voltage of 3 x 380/400/415VAC or 220/230/240VAC, with a power factor of >= 0.99 at full load. It maintains harmonic distortion below 4% at full linear load and provides a pure sinewave output in battery mode.
Is the Galleon III 33/31/11 compatible with different battery types or solar panels?
The Galleon III 33/31/11 is designed to work seamlessly with various battery types and can be integrated into solar power systems, ensuring flexibility in different power setups.
What are the physical specifications of the Galleon III 33/31/11?
The physical dimensions and weight of the Galleon III 33/31/11 are designed for optimal space utilization and ease of installation, although specific dimensions and weight details are not provided in the key specifications.
What are the installation requirements for the Galleon III 33/31/11?
Installation of the Galleon III 33/31/11 requires a stable environment with proper ventilation and adherence to electrical standards. It should be installed by a qualified technician to ensure safety and optimal performance.
What warranty does the Galleon III 33/31/11 come with?
The Galleon III 33/31/11 comes with a standard warranty that covers defects in materials and workmanship. Specific warranty terms should be confirmed with the retailer or manufacturer.
What certifications does the Galleon III 33/31/11 have?
The Galleon III 33/31/11 is certified with CE, EN 62040-1, IEC 62040-1, and EN 62040-2, ensuring compliance with international safety and performance standards.
What are the operating conditions for the Galleon III 33/31/11?
The Galleon III 33/31/11 operates efficiently within a specific temperature and humidity range, although exact values are not specified. It is designed to function reliably in typical indoor environments.
What are the key features and benefits of the Galleon III 33/31/11?
Key features of the Galleon III 33/31/11 include zero transfer time, pure sinewave output, and high efficiency with a power factor of >= 0.99. These features ensure reliable power supply and protection for sensitive equipment.