Voltronic Fortress 3phase UPS

The Fortress 3phase UPS from Voltronic Power is engineered to deliver robust and reliable power protection for critical applications. With a nominal voltage of 3 x 380/400/415 VAC and auto-sensing frequency, it ensures seamless operation across various environments.

Models Covered: 60K, 80K, 100K, 120K, 180K, 200K, 240K, 300K

Manufacturer: Voltronic Power Technology Corp.

Application: Ideal for data centers, industrial facilities, and telecommunications, the Fortress 3phase UPS provides consistent power regulation and protection against voltage fluctuations.

Three Phase Online UPS Backfeed detection built-in Dual-mains inputs
Download PDF Datasheet WhatsApp Us

Technical Specifications

Technical Specifications
Parameter 60K80K100K120K180K200K240K300K
Input
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range 110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load110-300 VAC @ 50% load; 184-276 VAC @100% load
Nominal Frequency 50/60Hz (Auto sensing)
Frequency Range 40Hz ~ 70Hz
Power Factor >= 0.99 @ 100% load
Harmonic Distortion (THDi) <5% @ 100% load
Output
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Regulation (Steady state) ≤ ± 1% Typical (balanced load)
Nominal Frequency 50/60Hz
Frequency Range (Synchronized range) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability ≤ 110% for 1 hour, 111% ~ 125% for 10 mins, 126%~150% for 1 min and >150% for 200ms
Harmonic Distortion ≤ 2% THD (Linear Load); ≤ 4% THD (Non-linear Load)
Efficiency
AC Mode 95%96%95.5%95.5%95.5%95.5%95.5%95.5%
ECO Mode 98%99%98.5%98.5%98.5%98.5%98.5%98.5%
Battery Mode 94%95.5%94.5%94.5%94.5%94.5%94.5%94.5%
Bypass
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range -30% ~ +20%
Frequency Range 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability ≤ 110% for 1 hour, 111% ~ 125% for 10 mins, 126%~150% for 1 min and >150% for 200ms
Battery Charging
Nominal Voltage +/- 192V ~ +/- 240V (Selectable)
Maximum Voltage +/- 240V (12V x 40 Pcs)
Minimum Voltage +/- 192V (12V x 32 Pcs)
Floating Charge Voltage 2.28V / Cell (2.25 ~ 2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current 18A (Adjustable)18A (Adjustable)24A (Adjustable)36A (Adjustable)54A (Adjustable)54A (Adjustable)72A (Adjustable)90A (Adjustable)
Physical
IP Class IP20, optional IP31
Dimension, D x W x H (mm) 1000x320x8001000x430x12001000x430x12001000x430x12001000x600x12001000x600x12001100x600x14751100x600x1475
Net Weight (Kgs) 94125169169249249360396
Operating Conditions
Operating Temperature 0-40°C
Operating Humidity < 95% and non-condensing
Altitude <1000m for Nominal power
Communication
Management Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Certifications
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3

Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.

Key Features

Backfeed detection built-in

Single power module on/off control through LCD panel

Pluggable power module design with front access

Parallel operation up to 4 units with common battery

Dual-mains inputs

Built-in 4 switches including Mains input, bypass input, output and maintenance bypass switch

Flexible battery configuration and adjustable charging current

Optional extra communication is available

Applications & Use Cases

Typical Applications

  • Data centers
  • Hospitals and medical facilities
  • Banks and financial institutions
  • Telecommunications
  • Factories and industrial facilities

Regional Installation Notes (United Arab Emirates)

Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.

  • Ensure adequate ventilation
  • Protection from direct sunlight
  • Regular maintenance recommended

Frequently Asked Questions

What are the main performance specifications of the Fortress 3phase UPS?

The Fortress 3phase UPS offers high efficiency with 95% in AC mode, 98% in ECO mode, and 94% in battery mode. It supports a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) and a power factor of >= 0.99 at full load.

Is the Fortress 3phase UPS compatible with different battery types or solar panels?

The Fortress 3phase UPS is designed to be compatible with various battery types. However, it does not directly support solar panels without additional equipment.

What are the physical specifications of the Fortress 3phase UPS?

The specific dimensions and weight of the Fortress 3phase UPS are not provided in the key specifications. Please refer to the product manual or contact Voltronic Power for detailed physical specifications.

What are the installation requirements for the Fortress 3phase UPS?

Installation of the Fortress 3phase UPS requires a stable environment with proper ventilation. It should be installed by a qualified technician to ensure compliance with electrical standards.

What is the warranty period for the Fortress 3phase UPS?

The Fortress 3phase UPS typically comes with a standard warranty period. Please check with Voltronic Power or your supplier for specific warranty terms and conditions.

What certifications and standards does the Fortress 3phase UPS comply with?

The Fortress 3phase UPS complies with IEC/EN 62040-1 and IEC/EN 62040-2 Category C3 standards, ensuring safety and performance reliability.

What are the operating conditions for the Fortress 3phase UPS?

The Fortress 3phase UPS is designed to operate efficiently within a wide frequency range of 40Hz to 70Hz. It should be used in environments with controlled temperature and humidity levels.

What are the key features and benefits of the Fortress 3phase UPS?

Key features of the Fortress 3phase UPS include high efficiency, robust voltage regulation, and excellent overload capability. These features ensure reliable power supply and protection for critical systems.