Voltronic EVOLUTION-400 / VOLTRONIC-EVOLUTION-600 / VOLTRONIC-EVOLUTION-800
Discover the Voltronic Power Evolution 400 with voltage options of 110/120VAC or 220/230/240VAC and auto-sensing frequency.
Technical Specifications
| Parameter | VOLTRONIC-EVOLUTION-400 | VOLTRONIC-EVOLUTION-600 | VOLTRONIC-EVOLUTION-800 |
|---|---|---|---|
| Electrical / AC Output Data | |||
| Rated Output Power (VA) | 400VA | 600VA | 800VA |
| Rated Output Power (W) | 240W | 360W | 480W |
| Input | |||
| Voltage | 110/120 VAC or 220/230/240 VAC | ||
| Voltage Range | 81-134VAC/89-145VAC or 162-268VAC/170-280VAC/177-290VAC | ||
| Frequency Range | 60/50 Hz (Auto sensing) | ||
| Output | |||
| AC Voltage Regulation (Batt. Mode) | ±10% | ||
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz | ||
| Transfer Time | Typical 2-6 ms, 10 ms max. | ||
| Waveform (Batt. Mode) | Simulated Sinewave | ||
| Battery | |||
| Typical Recharge Time | 4-6 hours recover to 90% capacity | ||
| Physical | |||
| Dimension, D x W x H (mm) | 245 x 163 x 90 | ||
| Net Weight (kgs) | 3.5 | 4.0 | 4.5 |
| Protection Features | |||
| Full Protection | Overload, discharge, and overcharge protection | ||
| Operating Conditions | |||
| Humidity | 0 to 90% Relative Humidity (Non-condensing) | ||
| Noise Level | Less than 40dB | ||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Compact size: Compact size
- Boost and buck AVR for: Boost and buck AVR for voltage stabilization
- Auto restart while AC is: Auto restart while AC is recovering
- Simulated sine wave output: Simulated sine wave output
- Off-mode charging: Off-mode charging
- Cold start function: Cold start function
- Generator compatible (option): Generator compatible (option)
- Optional 5V USB charging port: Optional 5V USB charging port
- Compact size for stand and: Compact size for stand and mounting flexibility
Frequently Asked Questions
What are the main performance specifications of the Evolution 400?
The Evolution 400 operates with a voltage of 110/120 VAC or 220/230/240 VAC and has a voltage range of 81-134VAC/89-145VAC or 162-268VAC/170-280VAC/177-290VAC. It features an auto-sensing frequency range of 60/50 Hz and provides a simulated sinewave output in battery mode.
Is the UPS compatible with different battery types or solar panels?
The UPS uses a 12 V 4.5 Ah battery and is not specifically designed for direct integration with solar panels. It is primarily intended for use with standard grid power.
What are the physical dimensions and weight of the UPS?
The UPS measures 245 x 163 x 90 mm and has a net weight of 3.5 kg. It does not have an IP rating, indicating it is not specifically rated for dust or water resistance.
What are the installation requirements for the UPS?
Installation requires a stable environment with a power source within the specified voltage range. Ensure adequate ventilation and avoid placing the UPS in direct sunlight or near heat sources.
What warranty information is available for this UPS?
Voltronic Power typically offers a standard warranty for their UPS products, covering manufacturing defects. Specific warranty terms should be confirmed with the retailer or distributor.
What certifications and standards does the UPS comply with?
The Evolution 400 complies with standard certifications, ensuring it meets industry safety and performance standards. Specific certifications can be confirmed with the manufacturer.
What are the operating conditions for temperature and humidity?
The UPS operates effectively in environments with 0 to 90% relative humidity (non-condensing) and should be kept in a temperature-controlled environment to ensure optimal performance.
What are the key features and benefits of this UPS?
Key features include overload, discharge, and overcharge protection, a typical transfer time of 2-6 ms, and a noise level of less than 40dB. These features ensure reliable performance and protection for connected devices.
What are the main performance specifications of the Evolution 600?
The Evolution 600 operates with a voltage of 110/120 VAC or 220/230/240 VAC and has a voltage range of 81-134VAC/89-145VAC or 162-268VAC/170-280VAC/177-290VAC. It features an auto-sensing frequency range of 60/50 Hz and provides a simulated sinewave output in battery mode.
What are the main performance specifications of the Evolution 800?
The Evolution 800 operates with a voltage of 110/120 VAC or 220/230/240 VAC and has a voltage range of 81-134VAC/89-145VAC or 162-268VAC/170-280VAC/177-290VAC. It features an auto-sensing frequency range of 60/50 Hz and provides a simulated sinewave output in battery mode.