Voltronic Power Solutions

Voltronic AXPERT-MAX-TWIN-8/E-TWIN-11/TWIN-12K

Discover the Axpert MAX TWIN 8K inverter by Voltronic Power with 230VAC regulation, 16000VA surge power, and 93% efficiency.

Models Covered: VOLTRONIC-AXPERT-MAX-TWIN-8K, VOLTRONIC-AXPERT-MAX-E-TWIN-11K, VOLTRONIC-AXPERT-MAX-TWIN-12K

Manufacturer: Voltronic Power Technology Corp.

Application: The Axpert MAX TWIN by Voltronic Power is a high-performance inverter designed for optimal energy conversion. With a robust AC voltage regulation of 230VAC ± 5% and a peak efficiency of 93%, this inverter ensures reliable power delivery for various applications. Ideal for residential and commercial use, the Axpert MAX TWIN is perfect for backup power systems, renewable energy setups, and off-grid installations.

Technical Specifications

Technical Specifications
Parameter VOLTRONIC-AXPERT-MAX-TWIN-8KVOLTRONIC-AXPERT-MAX-E-TWIN-11KVOLTRONIC-AXPERT-MAX-TWIN-12K
Additional Specifications
Circulation Current under No Load Condition Max 2A
DC Offset ≤100mV
Floating Charging Voltage 54Vdc
Low DC Cut-off Voltage 44Vdc
Max. Charging Current 120A
Max. Input Current 27A x 2 (MAX 40A)
Max. PV Array Open Circuit Voltage 500Vdc
Nominal DC Input Voltage 48Vdc
PV Array MPPT Voltage Range 90Vdc 450Vdc
Parallel Kit YES
Parallel communication CAN
Peak Efficiency 93%
Transfer time in parallel mode Max 50ms
Max parallel numbers 6
Parallel Capability YES, 6 units
Selectable Voltage Range 170-280 VAC (For Personal Computers)
Efficiency (Line Mode) >95% (Rated R load, battery full charged)
High Loss Frequency 65±1Hz
High Loss Return Frequency 63±1Hz
High Loss Return Voltage 270Vac±7V
High Loss Voltage 280Vac±7V
Low Loss Frequency 40±1Hz
Low Loss Return Frequency 42±1Hz
Low Loss Return Voltage 180Vac±7V (UPS); 100Vac±7V (Appliances)
Low Loss Voltage 170Vac±7V (UPS) 90Vac±7V (Appliances)
Max AC Input Current 60A
Max AC Input Voltage 300Vac
Max Output Current for 2nd output 40A
Nominal Input Frequency 50Hz/60Hz (Auto detection)
Nominal Input Voltage 230Vac
Output Short Circuit Protection Line mode: Circuit Breaker (70A) Battery mode: Electronic Circuits
Charging Current 150A UPS
Input Voltage Waveform Sinusoidal (utility or generator) Nominal
Overload Protection Surge
Safety Certification CE
Power Unbalance Ratio <5% 100% Load
DC Voltage DC Offset ≦100mV Power Limitation 55Vdc
Efficiency >95% ( Rated R load Line Mode
Output Frequency 60Hz or 50Hz Peak
Output Voltage Regulation 230Vac± 5%
Operating Temperature Range -10°C to 50°C
Electrical / AC Output Data
High DC Cut-off Voltage 66Vdc63Vdc66Vdc
High DC Recovery Voltage 64Vdc61Vdc64Vdc
Rated Output Power 8000W11000W8000W
Rated Power 8000W11000W Max. PV Array Open Circuit8000W
Start-up Voltage 80V +/- 5Vdc80V +/- 5Vdc Power Limitation PV Current MPPT temperature 75° 80°80V +/- 5Vdc
AC Output
AC Voltage Regulation (Batt. Mode) 230VAC ± 5%
Surge Power 16000VA22000VA24000VA
Efficiency (Peak) 93%
Transfer Time 10 ms (For Personal Computers), 20 ms (For Home Appliances)10ms typical (UPS);10 ms (For Personal Computers), 20 ms (For Home Appliances)
Waveform Pure sine wave
Optional DC Voltage 12 VDC ± 5%, 100W
Battery
Battery Voltage 48 VDC
Floating Charge Voltage 54 VDC
Overcharge Protection 66 VDC63Vdc Charging Algorithm 3-Step Charging Curve Time63 VDC
Solar Charger & AC Charger
Solar Charger Type MPPT
Maximum PV Array Power 11000W (5500W x 2)13000W (6500W x 2)18000W (Max. 12000W per tracker)
MPPT Range @ Operating Voltage 90 – 450 VDC
Maximum PV Array Open Circuit Voltage 500 VDC
Maximum PV Input Current 27A x 2 (MAX 40A)40A/27A (MAX 60A)40A/27A (MAX 60A)
Maximum Solar Charge Current 120A150A200A
Maximum AC Charge Current 120A150A200A
Maximum Charge Current 120A150A200A
Standard
Compliance Safety IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12
Physical
Dimension, D x W x H (mm) 147.4 x 432.5 x 553.6
Net Weight (kgs) 18.418.420
Communication Interface USB/RS232/RS485/WiFi/Dry-contact
Operating Environment
Humidity 5% to 95% Relative Humidity(Non-condensing)5% to 95%5% to 95% Relative Humidity(Non-condensing)
Operating Temperature -10°C to 50°C
Storage Temperature -15°C to 60°C-15°C~ 60°C-15°C to 60°C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Yemen

Market Yemen
Grid authority / regulator Public Electricity Corporation (PEC), Ministry of Electricity and Energy
Quotation currency YER
Support hours timezone Asia/Aden
Delivery & installation coverage Sana'a, Aden, Taiz, Al Hudaydah, Mukalla

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Status indication with RGB lights: Status indication with RGB lights
  • Dual outputs for smart load: Dual outputs for smart load management
  • Upgrade maximum PV current to: Upgrade maximum PV current to 60A for 12K model
  • Built-in WiFi with APP for: Built-in WiFi with APP for mobile monitoring and OTA firmware
  • Supports USB On-the-Go function: Supports USB On-the-Go function
  • Built-in BMS communication port: Built-in BMS communication port
  • Built-in meter calibration for optimized: Built-in meter calibration for optimized system operation
  • Battery independent design: Battery independent design
  • Built-in anti-dust kit: Built-in anti-dust kit
  • Optional DC output for DC: Optional DC output for DC fan, LED bulb, router and so on
  • Parallel operation with 6 units: Parallel operation with 6 units

Frequently Asked Questions

What are the main performance specifications of the Axpert MAX TWIN inverter?

The Axpert MAX TWIN inverter offers a peak efficiency of 93% and can handle a surge power of 16000VA. It maintains an AC voltage regulation of 230VAC ± 5% in battery mode.

Is the Axpert MAX TWIN compatible with different battery types and solar panels?

Yes, the inverter is compatible with a 48 VDC battery system and supports solar panels with a maximum PV array power of 11000W, utilizing MPPT technology for efficient solar energy conversion.

What are the physical specifications of the Axpert MAX TWIN inverter?

The physical dimensions and weight of the Axpert MAX TWIN are not specified in the provided details. However, it is designed to be robust and suitable for various installation environments.

What are the installation requirements for the Axpert MAX TWIN?

Installation requires a compatible 48 VDC battery system and solar panels within the MPPT range of 90 – 450 VDC. Ensure proper ventilation and adherence to local electrical standards.

What warranty is offered with the Axpert MAX TWIN inverter?

Voltronic Power typically offers a standard warranty for their inverters, but specific warranty details for the Axpert MAX TWIN should be confirmed with the retailer or manufacturer.

What certifications does the Axpert MAX TWIN have?

The Axpert MAX TWIN is certified under IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, and 61000-3-12, ensuring compliance with international safety and performance standards.

What are the operating conditions for the Axpert MAX TWIN?

The inverter is designed to operate efficiently in a wide range of environmental conditions, but specific temperature and humidity ranges are not detailed in the provided specifications.

What are the key features and benefits of the Axpert MAX TWIN?

Key features include pure sine wave output, fast transfer time of 10 ms for PCs, and 20 ms for home appliances, and advanced MPPT solar charging, making it ideal for both residential and commercial applications.