Voltronic Power AXPERT-IND-1.2/2.5/3.2/5.2/6.5KW
The Axpert IND 1.2KW is a hybrid solar inverter rated Axpert IND 1.2KW.
Technical Specifications
| Parameter | AXPERT-IND-1.2KW | AXPERT-IND-2.5KW | AXPERT-IND-3.2KW | AXPERT-IND-5.2KW | AXPERT-IND-6.5KW |
|---|---|---|---|---|---|
| Electrical / AC Output Data | |||||
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) | ||||
| AC Voltage Regulation (Battery Mode) | 230VAC ± 5% | ||||
| Max Efficiency | 90% | ||||
| Rated AC Power | 1200VA/1200W | 2500VA/2500W | 3200VA/3200W | 5200VA/5200W | 6500VA/6500W |
| Surge / Peak Power | 2400VA | 5000VA | 6400VA | 10400VA | 13000VA |
| Additional Specifications | |||||
| Maximum PV Input Current | 22A x 2 | ||||
| Maximum PV Array Open Circuit Voltage | 350 VDC | ||||
| Waveform | Pure sine wave | ||||
| Compliance Safety | CE; IEC 62116; IEC 61727 | ||||
| Transfer Time | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | ||||
| Solar Charger type | MPPT | ||||
| Floating Charge Voltage | 13.5 VDC | ||||
| Communication | |||||
| Communication Interface | RS232/RS485(BMS)/WiFi | ||||
| PV String Input Data | |||||
| Max PV Array Power | 2000W | 3000W | 4000W | 5500W | 8000W(4000W x 2) |
| Max PV Input Current | 13 | ||||
| Operating Conditions | |||||
| Relative Humidity | 5% to 95% | ||||
| Operating Temperature | -10°C to 50°C | ||||
| Storage Temperature Range | -15°C to 60°C | ||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.