Voltronic Power Solutions

Voltronic AXPERT-VM-II-PREMIUM-PLUS-8K/VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-1.5K/VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-3K/VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-4.2K/VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-6.2K

The Axpert VM II Plus 1.2KVA is a solar inverter rated 1.2KVA.

Models Covered: AXPERT-VM-II-PLUS-1.2KVA, AXPERT-VM-II-PLUS-2.5KVA, VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-8K, VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-1.5K, VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-3K, VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-4.2K, VOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-6.2K

Manufacturer: Voltronic Power

Application: The Axpert VM II Plus 1.2KVA is a solar inverter rated 1.2KVA. Every figure on this page is read from the manufacturer's manual for the Axpert VM II Plus series.

Technical Specifications

Technical Specifications
Parameter AXPERT-VM-II-PLUS-1.2KVAAXPERT-VM-II-PLUS-2.5KVAVOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-8KVOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-1.5KVOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-3KVOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-4.2KVOLTRONIC-AXPERT-VM-II-PREMIUM-PLUS-6.2K
AC Output
Peak Efficiency 93%93%90%90%93%90%90%
AC Output Regulation (Batt. Mode) 230VAC ± 5%
Efficiency (Peak) 93%
Transfer Time 10 ms (For Personal Computers); 20 ms (For Home Appliances)
Waveform Pure sine wave
Additional Specifications
No Load Power Consumption <35W
AC Charging Current (Max) 80Amp
Default Charging Current 60A
PV Voltage Accuracy 2V
Efficiency (Line Mode) >95% (Rated R load
High Loss Frequency 65±1Hz
High Loss Return Frequency 63±1Hz
High Loss Return Voltage 270Vac±7V
High Loss Voltage 280Vac±7V
Low Loss Frequency 40±1Hz
Low Loss Return Frequency 42±1Hz
Max AC Input Voltage 300Vac
Nominal DC Input Voltage 24Vdc
Nominal Input Voltage 230Vac
Voltage Range 90-280VAC.
Cold Start Voltage 23.0Vdc
Floating Charging Voltage 27Vdc
Input (Shore or Generator)
Output Short Circuit Protection 32A
Protection 26A
Safety Certification CE
Solar Charger Type MPPT
High DC Recovery Voltage 31Vdc
Output PVPVPVPVTemperature of internal converterPVPV
Input Voltage Waveform Sinusoidal (utility or generator)
Low Loss Return Voltage 100Vac±7V (Appliances)
Nominal Input Frequency 50Hz/60Hz (Auto detection)
Output Frequency 50Hz or 60Hz
Efficiency >95% ( Rated R load Line Mode
Output Voltage Regulation 230Vac± 5%
Output Voltage Waveform Pure Sine Wave
Operating Temperature -10°C to 50°C
Protective Class I
Electrical / AC Output Data
Rated Output Power 1.2KVA/ 1.2KW2.5KVA/ 2.5KW8000VA/8000W1500VA/1500W3000VA/3000W4200VA/4200W6200VA/6200W
Max. Output Fault Current 10A22A26A26A26A26A26A
Max. Output Overcurrent Protection 10A22A26A
Operating Conditions
Operating Temperature Range -10°C to 50°C
Storage Temperature -15°C~ 60°C
Humidity 5% to 95% Relative Humidity (Non-condensing)
Electrical Data
Output Power 8000VA/8000W1500W with PV & battery 1200W with battery only4200W with PV & battery 4000W with battery only6200W with PV & battery 5000W with battery only
AC Output No. Dual OutputsSingleSingleDual OutputsDual Outputs
Surge Power 16000VA3000VA6000VA8400VA12400VA
Battery Voltage 48 VDC12 VDC24 VDC48 VDC48 VDC
Floating Charge Voltage 54 VDC13.5 VDC27 VDC54 VDC54 VDC
Overcharge Protection 66 VDC16 VDC32 VDC63 VDC63 VDC
Maximum PV Array Open Circuit Voltage 500 VDC350 VDC450 VDC500 VDC500 VDC
Maximum PV Array Power 10000W (5000W x 2)2000W3000W5000W6500W
Maximum PV Input Current 22 A x 213 A13 A18 A18 A
MPP Range @ Operating Voltage 90~450 VDC30 ~ 300 VDC (Min. 60VDC without battery connected)30 ~ 400 VDC (Min. 60VDC without battery connected)30 ~ 450 VDC (Min. 60VDC without battery connected)90~450 VDC (Min. 100VDC without battery connected)
Maximum Solar Charge Current 120A100A100A120A100A
Maximum AC Charge Current 120A80A80A100A100A
Maximum Charge Current 120A100A100A120A120A
Mechanical Data
Dimension, D x W x H (mm) 141 x 322 x 49790 x 288 x 35790 x 288 x 357115 x 300 x 435115 x 300 x 435
Net Weight (kgs) 156.67.1910.4
Communication Interface RS232/RS485(BMS)/WiFi

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Sudan

Market Sudan
Grid authority / regulator Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum
Quotation currency SDG
Support hours timezone Africa/Khartoum
Delivery & installation coverage Khartoum, Omdurman, Port Sudan, Kassala, Nyala

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • Wide PV input range, starts: Wide PV input range, starts from 30VDC for 1.5K/3K/4.2K models
  • Built-in communication port for BMS: Built-in communication port for BMS
  • Built-in feed-in grid function: Built-in feed-in grid function
  • Built-in WiFi with APP for: Built-in WiFi with APP for remote monitoring and OTA firmware upgrade
  • Dual AC outputs only for: Dual AC outputs only for 4.2K/6.2K/8K models
  • Maximum charging current 100A/120A based: Maximum charging current 100A/120A based on models
  • Battery independent design: Battery independent design
  • Battery equalization function to optimize: Battery equalization function to optimize battery performance and extend lifecycle
  • Built-in anti-dust kit: Built-in anti-dust kit

Frequently Asked Questions

What are the main performance specifications of the Axpert VM II Premium+?

The Axpert VM II Premium+ offers an output power of 8000W with PV and battery, and 8000W with battery only. It has a peak efficiency of 93% and provides a pure sine wave output with an AC output regulation of 230VAC ± 5%.

Is the Axpert VM II Premium+ compatible with different battery types and solar panels?

Yes, the inverter is compatible with a 48 VDC battery system and supports MPPT solar chargers. It can handle a maximum PV array power of 10000W and a maximum PV array open circuit voltage of 500 VDC.

What are the physical specifications of the Axpert VM II Premium+?

The physical dimensions and weight of the Axpert VM II Premium+ are not specified here. Please refer to the product manual or contact Voltronic Power for detailed information.

What are the installation requirements for the Axpert VM II Premium+?

Installation should be performed by a qualified technician. Ensure proper ventilation and avoid exposure to direct sunlight or moisture. Follow the installation guidelines provided in the user manual for optimal performance.

What warranty does the Axpert VM II Premium+ come with?

The Axpert VM II Premium+ typically comes with a standard warranty. For specific warranty terms and conditions, please refer to the warranty card or contact Voltronic Power directly.

What certifications and standards does the Axpert VM II Premium+ meet?

The Axpert VM II Premium+ meets standard certifications, ensuring compliance with industry standards for safety and performance. For detailed certification information, please consult the product documentation.

What are the operating conditions for the Axpert VM II Premium+?

The inverter is designed to operate efficiently under standard environmental conditions. For specific temperature and humidity ranges, please refer to the user manual.

What are the key features and benefits of the Axpert VM II Premium+?

Key features include a pure sine wave output, MPPT solar charger compatibility, and a high peak efficiency of 93%. These features ensure reliable performance and efficient energy conversion.