Voltronic Power INFINISOLAR-SUPER-4KW
The InfiniSolar Super 4KW is a solar inverter rated 4KW. Every figure on this page is read from the manufacturer's manual for the InfiniSolar Super series.
Technical Specifications
| Parameter | INFINISOLAR-SUPER-4KW |
|---|---|
| Electrical / AC Output Data | |
| AC Start-up Voltage | 120-140 VAC |
| AC Input | 4000VA/4000W |
| Max AC Output Power | 4000VA/4000W |
| Max Conversion Efficiency (DC/AC) | 91% |
| Max AC Input Current | 18 A |
| AC Output Voltage | 230 VAC |
| Nominal Output Current | 17.4 A |
| Inrush Current | 17.4 A / 20ms |
| Adjustable Power Factor Range | 0.9 lead – 0.9 lag - |
| Auto Restart Voltage | 180 VAC |
| Input Voltage Range | 170-280 VAC |
| Grid / AC Frequency | 50 Hz / 60 Hz |
| Additional Specifications | |
| Maximum DC Power | 5000 W |
| Maximum AC Input Current | 40 A |
| Inrush Input Current | 40 A / 1ms |
| Power Factor | > 0.99 |
| Maximum Conversion Efficiency (DC/AC) | 96% |
| European Efficiency@ Vnominal | 95% |
| Maximum Charging Current | 80 A |
| Communication Port | USB/Dry contact |
| Intelligent Slot | Optional SNMP, Modbus and AS-400 cards |
| Humidity | 0 ~ 90% RH (Non-condensing) |
| Altitude | 0 ~ 1000 m** |
| PV String Input Data | |
| Nominal DC Voltage | 360 VDC |
| Max PV / DC Voltage | 580 VDC |
| Start-up Voltage | 116 VDC / 150 VDC |
| MPPT Voltage Range | 120 VDC 500 VDC ~ |
| MPPT Voltage Range at Full Load | 280 VDC~500 VDC |
| Max PV Short-Circuit Current | 25 A |
| Battery Data | |
| Working DC Voltage Range | 100 VDC~500 VDC |
| Protection Features | |
| Maximum Output Fault Current | 52 A / 1ms |
| Max. Output Overcurrent Protection | 52 A |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Netherlands
| Market | Netherlands |
| Grid authority / regulator | ACM Netherlands |
| Quotation currency | EUR |
| Support hours timezone | Europe/Amsterdam |
| Delivery & installation coverage | Amsterdam, Rotterdam, The Hague, Utrecht |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Netherlands that is ACM Netherlands. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.