The Galleon III Rack/Tower UPS from Voltronic Power is engineered to deliver superior power protection with its versatile voltage range of 200-240 VAC. Designed for both rack and tower configurations, it ensures consistent performance with an AC voltage regulation of ± 1% in battery mode.
Technical Specifications
| Parameter | Galleon III 1K-2(BL) | Galleon III 1K-3(BL) | Galleon III 1.5K(L) | Galleon III 2K-4(BL) | Galleon III 2K-6(BL) | Galleon III 3K(L) |
|---|---|---|---|---|---|---|
| Input | ||||||
| Nominal Voltage | 200/208/220/230/240 VAC | |||||
| Input Voltage Range | 110 – 300 VAC (Based on load at 50%) | |||||
| Frequency Range | 40 Hz ~ 70 Hz | |||||
| Power Factor | ≥ 0.99 @ nominal voltage (100% load) | |||||
| THD | ≤ 5% @ nominal voltage (100% load) | |||||
| Output | ||||||
| Output Voltage | 200/208/220/230/240 VAC | |||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | |||||
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz | |||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||||
| Current Crest Ratio | 3:1 | |||||
| Harmonic Distortion | ≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) | |||||
| Transfer Time | 4 ms (Typical) | |||||
| Waveform (Batt. Mode) | Pure Sinewave | |||||
| Efficiency | ||||||
| ECO mode @ full charged battery | 96% | 97% | 97% | 97% | 93% | 94% |
| AC Mode @ full charged battery | 92% | 92% | 92% | 92% | 91% | 91% |
| Battery Mode | 86% | 89% | 89% | 88% | 89% | 91% |
| Battery | ||||||
| Battery Type | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah |
| Numbers | 2 | 3 | 3 | 4 | 6 | 6 |
| Typical Recharge Time | 4 hours recover to 90% capacity for internal battery | |||||
| Charging Current (CC) | 1.5A | |||||
| Charging Voltage (V) | 27.4VDC ± 1% | 41.0VDC ± 1% | 41.0VDC ± 1% | 54.8VDC ± 1% | 82.2VDC ± 1% | 82.2VDC ± 1% |
| Physical | ||||||
| Dimension, D x W x H (mm) | 310 x 438 x 88 | 410 x 438 x 88 | 510 x 438 x 88 | 510 x 438 x 88 | 550 x 438 x 88 | 550 x 438 x 88 |
| Net Weight (kgs) | 11 | 13.5 | 14.7 | 19 | 23 | 26.7 |
| Operating Conditions | ||||||
| Humidity | 20-95 % RH @ 0-40°C (non-condensing) | |||||
| Noise Level | Less than 50dBA @ 1 Meter with Fan speed control | |||||
| Communication | ||||||
| Smart RS-232 or USB | Supports Windows® family, Linux, Unix and MAC | |||||
| Optional external slot | Power management from SNMP manager and web browser | |||||
| Certifications | ||||||
| Standard | CE (EMC: EN62040-2 C2) | |||||
Note: Specifications are based on the official Voltronic Power datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
True double-conversion
Microprocessor control optimizes reliability
Input power factor correction 0.99
Output power factor 1.0
50/60 Hz Frequency Converter Mode
Wide input voltage (110 V – 300 V)
ECO mode for energy saving
Smart battery charger design to optimize battery performance
Applications & Use Cases
Typical Applications
- Data centers
- Hospitals and medical facilities
- Banks and financial institutions
- Telecommunications
- Factories and industrial facilities
Regional Installation Notes (United Arab Emirates)
Climate Suitability: Suitable for United Arab Emirates's hot climate with reliable performance at high temperatures.
- Ensure adequate ventilation
- Protection from direct sunlight
- Regular maintenance recommended
Frequently Asked Questions
What are the main performance specifications of the Galleon III Rack/Tower UPS?
The Galleon III Rack/Tower UPS offers a nominal voltage range of 200/208/220/230/240 VAC and operates with a power factor of ≥ 0.99 at nominal voltage with 100% load. It provides high efficiency with 96% in ECO mode and 92% in AC mode with a fully charged battery.
Is the Galleon III Rack/Tower UPS compatible with different battery types or solar panels?
The Galleon III Rack/Tower UPS is primarily designed for use with standard UPS batteries. For solar panel integration, additional equipment may be required to ensure compatibility.
What are the physical specifications of the Galleon III Rack/Tower UPS?
The Galleon III Rack/Tower UPS features a compact design suitable for both rack and tower installations. Specific dimensions and weight details can be obtained from the product manual or manufacturer's website.
What are the installation requirements for the Galleon III Rack/Tower UPS?
Installation of the Galleon III Rack/Tower UPS requires a stable environment with adequate ventilation. It should be installed by a qualified technician to ensure proper setup and safety compliance.
What warranty does the Galleon III Rack/Tower UPS come with?
The Galleon III Rack/Tower UPS typically comes with a standard warranty period, which can vary by region. Customers should check with their local distributor for specific warranty terms.
What certifications does the Galleon III Rack/Tower UPS have?
The Galleon III Rack/Tower UPS is CE certified, ensuring it meets European safety, health, and environmental protection standards.
What are the operating conditions for the Galleon III Rack/Tower UPS?
The Galleon III Rack/Tower UPS is designed to operate in a temperature range that ensures optimal performance. It should be kept in a controlled environment with moderate humidity levels.
What are the key features and benefits of the Galleon III Rack/Tower UPS?
Key features of the Galleon III Rack/Tower UPS include its pure sinewave output in battery mode, low harmonic distortion, and fast transfer time of 4 ms. These features ensure reliable power protection and efficiency.